    2021-8-2 · Dental handpiece air turbines, which are also known as air driven handpiece motors, often showcase a motor that ranges from 5,000 rpm to 20,000 rpm. Pressured air and water are often featured as a coolant. Many air driven handpiece motors also provide a light source.

    Get Price
  • High Speed Air Turbine Handpiece - Brasseler USA

    2021-6-24 · 3) Do not exceed the air pressure of 36psi (2.5 bar). Air pressure readings must be checked at the coupling joint as shown in Fig. 3. 1) Align the pipes of the coupling and the pipe holes of the hose, and push the coupling onto the hose. Hold the coupling tightly and fasten the nut of the hose securely. (Fig. 2) 2) Insert the handpiece ˜rmly ...

    Get Price
  • Replacement Turbines - Dental Handpiece Repair Solutions

    Replacement Turbines. HandpieceSolutions.com carries the highest quality turbine assemblies in the market. Made from heat treated stainless steel and precision ground spindles, our turbines are electronically balanced, robust, serialized for accurate traceability, and bur retention is better or equal to original equipment.

    Get Price
  • Midwest Quiet-Air Standard Chuck Dental Handpiece

    Midwest Quiet-Air Standard Turbine for Midwest Standard Quiet-Air Dental Handpieces. Our replacement turbines are the perfect fit for your handpiece. For over 20 years, we have served the dental community with expert handpiece repairs. We personally build each turbine with the highest quality parts available.

    Get Price
  • Non-lubrication dental lab air turbine handpiece

    2020-1-9 · Non-lubrication dental lab air turbine handpiece Thank you purchasing the PRESTO. Please read this operation manual prior to use for safety and keep this within user's reach. OM-T0057E Rev.A PRESTPRESTOO OPERATION MANUAL • The recommended air pressure to the handpiece is 0.25MPa (2.5kgf/cm2) at the pressure gauge, higher air

    Get Price
  • High Speed Air Turbine Handpiece - NSK-Nakanishi

    2021-1-28 · High Speed Air Turbine Handpiece S-Max pico OM-T0496E 001. 1 ENGLISH ... · Do not exceed the Air Pressure recommended in specification below as bur breakage or wear may occur if it exceeds the Air Pressure. ... Replace the Head Cap and firmly screw into …

    Get Price
  • Handpiece-Turbines.com: High Quality Dental Handpiece ...

    Dental Handpiece Turbines for KaVo, Midwest, Star, W&H, ADEC, Sirona, Lares, Kinetic, Impact-Air, NSK, Brasseler, Bien-Air, Mk-Dent, Henry Schein, Dentex, Japanese ...

    Get Price
  • HIGH SPEED AIR TURBINE HANDPIECE - Brasseler USA

    2019-2-26 · Set air pressure at handpiece connection to 38 - 42 psi. 4 EN • Exceeding recommended air pressure may result in premature cartridge failure.

    Get Price
  • High Speed Air Turbine Handpiece -

    2019-10-15 · 3. Setting of Air & Water Supply Pressure Measure the supply pressure at the handpiece hose connection point and set the pressure to the value specified on the specification table. (Fig. 1) For Multi Gauge information refer to Option Parts List. Warning Caution • Do not exceed the optimum pressure specified on the specification table.

    Get Price
  • Handpiece-Turbines.com: Bien-Air TD783 Fiction Grip Lab ...

    Bien-Air TD783 Fiction Grip Lab Turbine for Bien-Air TD783 Fiction Grip Lab Handpiece. Our replacement turbines are the perfect fit for your handpiece. For over 20 years, we have served the dental community with expert handpiece repairs. We personally build each turbine with the …

    Get Price
  • High Speed Air Turbine Handpiece - NSK-Nakanishi

    2020-4-16 · Handpiece Coupling OM-T0436E High Speed Air Turbine Handpiece Caution · When operating the handpiece always consider the safety of the patient. · Check for vibration, noise and overheating outside the patient's mouth. If any abnormalities are found do not operate. Contact authorized dealer for service.

    Get Price
  • Amazon Best Sellers: Best Dental Handpiece Turbines

    MTI Dental 50326 336/338 Push-Button Replacement Canister Turbine #5 MEDIDENTA Meditorque Elite 4:1 Prophy Nose Cone, 5,000rpm 4:1 Low-Speed Dental Handpiece 4 Holes, Push-Pull Friction Grip Chuck- Low Vibration and Ergonomically Designed for …

    Get Price
  • Non-lubrication dental lab air turbine handpiece

    2020-1-9 · Non-lubrication dental lab air turbine handpiece Thank you purchasing the PRESTO. Please read this operation manual prior to use for safety and keep this within user's reach. OM-T0057E Rev.A PRESTPRESTOO OPERATION MANUAL • The recommended air pressure to the handpiece is 0.25MPa (2.5kgf/cm2) at the pressure gauge, higher air

    Get Price
  • HIGH SPEED AIR TURBINE HANDPIECE - Brasseler USA

    2019-2-26 · Operating Air Pressure 38 – 42 psi 38 – 42 psi Operating Speed 405,000 – 420,000 rpm 405,000 – 420,000 rpm Connection Type Brasseler fiber-optic Brasseler non-optic Power 20 W 20 W Weight 50 g 50 g Head Height 12.5 mm 12.5 mm Head Diameter 10.5 mm 10.5 mm AIR PRESSURE Set air pressure at handpiece connection to 38 - 42 psi.

    Get Price
  • Beyes AirLight M600-M Autochuck Dental Handpiece

    Beyes AirLight M600-M Turbine for Beyes AirLight M600-M Push-Button Dental Handpiece. Our replacement turbines are the perfect fit for your handpiece. For over 20 years, we have served the dental community with expert handpiece repairs. We personally build each turbine with the …

    Get Price
  • High Speed Air Turbine Handpiece -

    2019-10-15 · 3. Setting of Air & Water Supply Pressure Measure the supply pressure at the handpiece hose connection point and set the pressure to the value specified on the specification table. (Fig. 1) For Multi Gauge information refer to Option Parts List. Warning Caution • Do not exceed the optimum pressure specified on the specification table.

    Get Price
  • PRESTO II - LABORATORY TURBINE SET - NSK - Depósito

    2021-8-12 · The easy to use air turbine handpiece is lightweight and compact, measuring only 130mm. Free 360º rotation handpiece. The ergonomically designed handle ensures comfort and ease of operation even in the most demanding procedures. Features: Uses FG turbine burs mandrel Ø 1.6mm; Turbine speed: up to 320,000 RPM. Recommended air pressure: 2.5 - 3 ...

    Get Price
  • High Speed Air Turbine - NSK-Nakanishi Latin America

    2021-1-28 · Set the Air pressure at the arrowed point on Fig. 1 and Fig. 2. The setting values are on the specification table. Do not exceed the recommended air pressure. Set the Multi Gage between turbine and hose, and set and measure the air pressure. (Multi Gauge for Midwest 4 hole: Order No. Z109400, Multi Gauge for Borden 2 hole: Order No. Z109200)

    Get Price
  • How to extend life of Dental Instrument - Dental handpices

    2021-8-9 · Always pay attention to the manufacturer’s guidelines on air pressure and follow them strictly, as excessive air pressure could cause damage to the turbine bearings. Always maintain a properly working autoclave. It’s important for the quality of your dental …

    Get Price
  • Star 430 Series High Speed Handpieces

    Star delivers quiet, reliable power in a sleek, durable high speed handpiece. Learn more about the Star 430 series dental handpieces.

    Get Price
  • Non-lubrication dental lab air turbine handpiece

    2020-1-9 · Non-lubrication dental lab air turbine handpiece Thank you purchasing the PRESTO. Please read this operation manual prior to use for safety and keep this within user's reach. OM-T0057E Rev.A PRESTPRESTOO OPERATION MANUAL • The recommended air pressure to the handpiece is 0.25MPa (2.5kgf/cm2) at the pressure gauge, higher air

    Get Price
  • Instructions for replacement highspeed turbine for use ...

    2012-7-30 · Instructions for replacement highspeed turbine for use with Midwest Quiet Air™ Power Lever™ (latch) autochuck handpiece, Quiet Air™ push button handpiece, & Quiet Air™ wrench chuck handpiece (Item #15-94, 15-941, 15-96, 15-82, & 15-821) IMPORTANT - READ BEFORE PROCEEDING Before replacing turbine, carefully examine handpiece head for dents.

    Get Price
  • Instructions for replacement highspeed turbine for use ...

    2012-7-31 · Instructions for replacement highspeed turbine for use with Midwest Quiet Air™ Power Lever™ (latch) autochuck handpiece & Quiet Air™ wrench chuck handpiece (Item #15-941 and 15-821) IMPORTANT - READ BEFORE PROCEEDING Before replacing turbine, carefully examine handpiece head for dents. If there is any evidence of dents in the head, return ...

    Get Price
  • High Speed Air Turbine Handpiece - Brasseler USA

    2019-2-26 · Indications for Use: The NLXK Turbine is an air-powered dental handpiece intended for removing carious material, reducing hard tooth structure, cavity preparation, finishing tooth preparations and restorations and polishing teeth. 2. Precautions for handling and operation Please read these precautions carefully and use only as intended or ...

    Get Price
  • Push-Button Canister Turbine - MTI Dental

    MTI Dental Turbines feature ceramic-bearing technology for quiet and smooth, extended operation! An ideal replacement turbine – engineered for long life and exceptional torque. ... Handpiece Compatibility: MTI Dental 336 Push-Button High Speed Handpieces; MTI Dental 338 Push-Button Non-Fiber-Optic High Speed Handpieces; MTI Dental 338 Push ...

    Get Price
  • Impact Air 45 Replacement Turbine (Genuine)

    Product Features . Genuine push button turbine for Impact Air 45 Surgical high speed handpiece. Come with 2 O´rings and washers; 3 month manufacturers´ warranty

    Get Price
  • Factors Affecting Dental Air-Turbine Handpiece Bearing ...

    2012-7-1 · Air-turbine handpieces have been used for most dental cutting procedures for more than 50 years since the invention of the Borden Air rotor in 1957. 1 Although some improvements such as push-button bur release, swivel coupling, and fiber-optic illumination have made it more convenient for use, the main component, a turbine rotor supported by two miniature ball bearings, remains unchanged. 1 ...

    Get Price
  • Dental Air Compressor Guide - Eclipse Dental Engineering

    The Dental Air Compressor is distinct to dental surgeries as they lower the dew point of the compressed air, removing impurities via an inline filtration system and removing moisture from the air through a compressed air dryer to protect your handpiece, ensure dry air from the 3:1 and eliminate bacteria. Your practice is dependent on a steady ...

    Get Price
  • Repairs – Crazy Handpiece

    Your handpiece will undergo our meticulous cleansing process to remove debris from air/water lines & exhaust lines. All debris will be removed from head & back cap for maximum repair efficiency. Replacement of dental bearings, Orings, wave washers, impeller. Standard chuck replaced if needed. (Please note if yo

    Get Price
  • Impact Air 45 Replacement Turbine (Genuine)

    Product Features . Genuine push button turbine for Impact Air 45 Surgical high speed handpiece. Come with 2 O´rings and washers; 3 month manufacturers´ warranty

    Get Price
  • Instructions for replacement highspeed turbine for use ...

    2012-7-31 · Instructions for replacement highspeed turbine for use with Midwest Quiet Air™ Power Lever™ (latch) autochuck handpiece & Quiet Air™ wrench chuck handpiece (Item #15-941 and 15-821) IMPORTANT - READ BEFORE PROCEEDING Before replacing turbine, carefully examine handpiece head for dents. If there is any evidence of dents in the head, return ...

    Get Price
  • High Speed Air Turbine Handpiece - Brasseler USA

    2019-2-26 · Indications for Use: The NLXK Turbine is an air-powered dental handpiece intended for removing carious material, reducing hard tooth structure, cavity preparation, finishing tooth preparations and restorations and polishing teeth. 2. Precautions for handling and operation Please read these precautions carefully and use only as intended or ...

    Get Price
  • Palisades Dental LLC.

    Q: What air pressure (in psi) should be used to run the IMPACT AIR 45 ®? A: 32 to 40 psi is recommended for optimum performance. Q: Can a chem-clave be used for sterilization? A: Yes. However, it is not recommended. It will sterilize the handpiece, but the chemicals will shorten the life of the turbine.

    Get Price
  • Factors Affecting Dental Air-Turbine Handpiece Bearing ...

    2012-7-1 · Air-turbine handpieces have been used for most dental cutting procedures for more than 50 years since the invention of the Borden Air rotor in 1957. 1 Although some improvements such as push-button bur release, swivel coupling, and fiber-optic illumination have made it more convenient for use, the main component, a turbine rotor supported by two miniature ball bearings, remains unchanged. 1 ...

    Get Price
  • How to maintain dental handpiece

    2017-12-11 · 11. It is important to follow the manufacturer’s guidelines on air pressure. Excessive air pressure could cause damage to the turbine bearings. 12. Always maintain a properly working autoclave. It’s important to check the handpiece coupler on the dental hose as well, at least once a week. O-rings should all be present and in good condition.

    Get Price
  • Discharge of lubricant from air turbine handpieces ...

    2005-5-28 · Each handpiece was then supplied with compressed air at the manufacturer's recommended operating pressure , controlled and monitored as before. After running for …

    Get Price
  • 1. - morita.com

    2018-8-30 · Handpiece Connection TWINPOWER TURBINE 4H (PAR-4H*-O) *MORITA 4H coupling Models Type PAR-4HEX-O PAR-4HX-O PAR-4HUEX-O PAR-4HUMX-O Bearing Ball bearing Chuck Push chuck Cartridge Capsule cartridge Rotor cartridge Air Pressure [MPa] (at handpiece end) 0.20 – 0.29 Recommended Air Pressure [MPa] (at handpiece end) 0.23 – 0.25

    Get Price
  • PERFORMANCE OF HIGH-SPEED DENTAL HANDPIECES

    1999-9-1 · The authors investigated the performance of nine commercially available high-speed air-turbine dental handpieces subjected to 1,000 simulated clinical uses and sterilizations. Methods Six new handpieces from each of nine different models were subjected to simulated clinical use with a custom-made handpiece wear tester and then autoclaved.

    Get Price
  • High Speed Air Turbine Handpiece - Atlas Resell

    2020-4-9 · 2. Setting of Air & Water Supply Pressure Measure the supply pressure at the handpiece hose connection point and set the pressure to the value specified on the specification table. (Fig. 1) *Multi Gauge : Midwest 4 Hole Order code Z109400 Borden2/3 Hole Order code Z109200 CAUTION Do not use air contaminated by dust, moisture and oil. WARNING

    Get Price
  • High Speed Air Turbine

    2020-1-9 · Water Pressure Chip Air Pressure Optic 380,000~450,000min Ø 12.1mm X 13.3 mm Initial Setting - Service Engineer Set the Air pressure at the location indicated in Fig. 1. The setting values are on the specification table. Do not exceed the recommended air pressure. CAUTION · Be sure to hold the handpiece firmly to prevent the handpiece from ...

    Get Price
  • W&H - Primea Advanced Air turbine

    With the Primea Advanced Air you can perform this sensitive step with a constantly low bur speed of just 60,000 rpm. This allows you to profile the preparation surface even more minimally invasively and finish the preparation margins with even more control than with a classic turbine handpiece.

    Get Price
  • W&H - Alegra Dental Turbine handpieces

    Dental turbine handpiece with ceramic ball bearings, triple spray and push-button chucking system, for FG burs Ø 1.6 mm (ISO 1797-1) Head size: Ø 10.4 mm. Power*: 16 Watt. Speed*: 390,000 -1. TE-97. REF 30068000. Dental turbine handpiece. with Roto Quick connection. TE-97 BC.

    Get Price
  • Characterizing the performance of dental air-turbine ...

    2008-1-1 · The dental air-turbine handpiece rapidly gained widespread acceptance by the dental profession after its introduction in the late 1950s and it continues to be used as the main means of carrying out cutting work in clinical dental practice, whether of tooth tissue or restorative materials.

    Get Price
  • Dorit high speed dental handpiece maintenance - Henan ...

    2018-3-5 · 1. Each time you use the handpiece, you must carefully check whether the equipment compatible, the work is normal, before use to check water pressure, air pressure is consistent with product requirements. Dorit high-speed mobile phone using the water pressure of 198Kpa (2kg), pressure of 277-316Kpa (2.8-3.2kgf cm2). 2.

    Get Price
  • Midwest Tradition Quiet-air MIDWEST Installation ...

    2021-8-24 · The handpiece delivers designed speed and torque when operated with clean, filtered, moisture-free air at the recommended operating pressure of 30 p.s.i. (2.0 Atm.). Air pressure should be measured at the handpiece end of the hose. Water Supply Recommendations It is highly recommended that all dental water supply systems conform to applicable ...

    Get Price
  • Dental Air Turbine Performance Study Using CFD and ...

    Dental air turbine handpieces have been widely used in clinical dentistry for over 30 years, however, little work has been reported on their performance.

    Get Price
  • Dental (LED)High Speed Handpiece Turbine (Quick

    This is a dental High Speed turbine handpiece with Quick Coupler 4 holes which is fit NSK QD-J High Speed Handpiece 2.Both handpiece and quick coupling are autoclavable, which is suitable for disinfection of high-temperature steam at 135℃ ,conform to modern clinical requirement.

    Get Price
  • DENTAL 45°DEGREE SURGICAL High Speed Turbine

    PicClick Insights - Dental 45°Degree Surgical High Speed Turbine Handpiece Push 4 Hole Fit NSK Kavo PicClick Exclusive Popularity - 42,411 views, 13.0 views per day, 3,266 days on eBay. Super high amount of views. 4,245 sold, 8 available.

    Get Price
  • Midwest Tradition Quiet-air MIDWEST Installation ...

    2021-8-24 · The handpiece delivers designed speed and torque when operated with clean, filtered, moisture-free air at the recommended operating pressure of 30 p.s.i. (2.0 Atm.). Air pressure should be measured at the handpiece end of the hose. Water Supply Recommendations It is highly recommended that all dental water supply systems conform to applicable ...

    Get Price
  • W&H - Primea Advanced Air turbine

    With the Primea Advanced Air you can perform this sensitive step with a constantly low bur speed of just 60,000 rpm. This allows you to profile the preparation surface even more minimally invasively and finish the preparation margins with even more control than with a classic turbine handpiece.

    Get Price
  • EXPERTtorque™ Mini LUX E675 L Expert ... - KaVo Dental

    2021-8-21 · Recommended air pressure 41 psi (2.8 bar) 420,000 rpm 2 year warranty - 2.5 year warranty if maintained using the KaVo QUATTROcare™ Plus Handpiece Maintenance System

    Get Price
  • W&H - Alegra Dental Turbine handpieces

    Dental turbine handpiece with ceramic ball bearings, triple spray and push-button chucking system, for FG burs Ø 1.6 mm (ISO 1797-1) Head size: Ø 10.4 mm. Power*: 16 Watt. Speed*: 390,000 -1. TE-97. REF 30068000. Dental turbine handpiece. with Roto Quick connection. TE-97 BC.

    Get Price
  • Dorit high speed dental handpiece maintenance - Henan ...

    2018-3-5 · 1. Each time you use the handpiece, you must carefully check whether the equipment compatible, the work is normal, before use to check water pressure, air pressure is consistent with product requirements. Dorit high-speed mobile phone using the water pressure of 198Kpa (2kg), pressure of 277-316Kpa (2.8-3.2kgf cm2). 2.

    Get Price
  • Dental Air Turbine Performance Study Using CFD and ...

    Dental air turbine handpieces have been widely used in clinical dentistry for over 30 years, however, little work has been reported on their performance.

    Get Price
  • MIDWEST Stylus Standard - DENTSPLY

    2021-8-23 · Air Requirements The handpiece delivers designed speed and torque when operated with clean, filtered, moisture-free air at the recommended operating pressure of 40 psi (2.7 Atm.) for 180S, 360S, 540S series and 42 psi (2.9 Atm.) for 181S, 361S, 541S series.Air pressure should be measured at the handpiece end of the hose. Have your dealer or ...

    Get Price
  • American Dental Accessories

    One reason this might be happening is poor, infrequent, or inadequate maintenance, which will cause premature turbine failure. Also, make sure you have the correct drive air pressure (it shouldn't be above 40 psi). Excessive drive air pressure is a common cause of failure (damages your bearings and drastically shortens the life of your turbine).

    Get Price
  • Impact Air 45 Turbine

    Buy Impact Air 45 turbine. Premium Handpiece Parts sells quality dental parts, turbines, dental handpiece parts and products. Call us at 312-788-7398.

    Get Price
  • YABANGBANG DENTAL 45 Degree Surgical High Speed

    Yabangbang Dental 45 Degree Surgical High Speed Handpiece Push Button 4Hole YCM4 ?USA STOCK 45° Angle 24H Track FG1.6mm Fit NSK Turbine 22.72 Buy It Now or Best Offer 7d 16h , 3.79 Shipping , 30-Day Returns, eBay Money Back Guarantee

    Get Price
  • W&H - Dental Handpieces - What should you look for

    In the air system a distinction is made between a turbine and an air motor. With turbines the bur is directly driven by a rotor. The rotor has an impeller powered by compressed air. Turbines reach an idle speed of up to 400,000 min-1. The working speed depends on the pressure exerted and is approximately half the idle speed - i.e. approx ...

    Get Price
  • The Turbine Source - Premium Dental Replacement Turbines

    The Turbine Source provides dental handpiece turbines for Star, Kavo, Midwest, W&H, NSK, Lares, and Sirona. The Turbine Source has offered premium handpiece turbines and expert technical support for over 28 years. Our highspeed handpiece turbines are built to exacting standards with industry leading Myonic bearings.

    Get Price
  • Air handpiece - All medical device manufacturers - Videos

    air straight. dental prophylaxis handpiece. DBI 5 SGII. Speed: 0 rpm - 5,000 rpm. The DBI 5 SGII Polisher is designed for Prophylaxis Application. Compact and lightweight Polisher has speeds up to 5,000 rpm to prevent stripping the gears of commonly used Disposable Prophy Angles and minimizes paste splatter.

    Get Price
  • Midwest Tradition Quiet-air MIDWEST Installation ...

    2021-8-18 · The handpiece delivers designed speed and torque when operated with clean, filtered, moisture-free air at the recommended operating pressure of 30 p.s.i. (2.0 Atm.). Air pressure should be measured at the handpiece end of the hose. Water Supply Recommendations It is highly recommended that all dental water supply systems conform to applicable ...

    Get Price
  • Dental Push Fast High Speed LED Handpiece Ceramic

    2020-8-20 · Features for 2/4 Holes dental handpiece E-generator LED handpiece. LED handpiece integrate E-generator: 1eac. SKU:180211(Fit Denshine handpiece of 180778/180779). AIR PRESSURE AT THE GAUGE IN THE DENTAL UNIT.

    Get Price
  • MIDWEST Stylus Standard - DENTSPLY

    2021-8-23 · Air Requirements The handpiece delivers designed speed and torque when operated with clean, filtered, moisture-free air at the recommended operating pressure of 40 psi (2.7 Atm.) for 180S, 360S, 540S series and 42 psi (2.9 Atm.) for 181S, 361S, 541S series.Air pressure should be measured at the handpiece end of the hose. Have your dealer or ...

    Get Price
  • Dental Handpiece Repair and Sales - Dental Equipment - DD

    Handpiece repair. With over 70 years of experience in handpiece repair and servicing, DD’s quality promise is stronger than ever. Alongside standard cartridge replacements and handpiece, motor and sonic scaler repairs – there’s also the option to upgrade to DD’s three service options, including our Premier Refresh Plan – which uses only original manufacturers parts.

    Get Price
  • dental handpiece,ultrasonic scaler,dental equipment ...

    2020-2-29 · ball-type gas turbine operating practices, common faults and troubleshooting First, the operating practices 1. Turbine drive air pressure for the compressed air input into the mobile phone must be dry and clean, the air pressure in the 0.25-0.32MPa, otherwise, the pressure is too low, dental hand piece the phone weak rotation, pressure is too high, speed mobile bearing wear.

    Get Price
  • Main Factors You Should Look For When Buying Dental ...

    Your Discount Dental Supplies Online China Supplier! Sign Up Login; My Account. Address Book; Wish List; Order History; Register; Login; Wish List (0)

    Get Price
  • Handpiece maintenance 101

    2015-4-10 · The high-speed dental handpiece is, without a doubt, one of the most commonly used and critical instruments in dental practices. Used in nearly every dental procedure, proper maintenance is essential to ensure that both the handpiece and cutting bur provide optimal performance each time they are used. Due to the variety in frequency, length, and type of use, as well as the hard materials that ...

    Get Price
  • W&H - Dental Handpieces - What should you look for

    In the air system a distinction is made between a turbine and an air motor. With turbines the bur is directly driven by a rotor. The rotor has an impeller powered by compressed air. Turbines reach an idle speed of up to 400,000 min-1. The working speed depends on the pressure exerted and is approximately half the idle speed - i.e. approx ...

    Get Price
  • Tech Talk: Dental Handpieces - firstimpressionsmag.com

    Handpiece basics The power of a handpiece is a function of torque and turbine speed. High-speed air turbine handpieces commonly operate between 27-42 psi, with operating speeds of 300,000-500,000 rpm. These handpieces are used with a “brush” or “feather” stroke to …

    Get Price
  • M600 & M700 AirLight Highspeed Handpiece Series

    2012-2-8 · Note: This handpiece should only be used on dental delivery systems that provide fil-tered and regulated air and water. Filtration of 25 microns is recommended. Water & Air Adjustment Coolant Water :Adjust the water volume at the delivery unit to obtain a satisfactory spray mist. Air Pressure : The operating pressure is 35 psi.

    Get Price
  • MIDWEST Stylus Standard - DENTSPLY

    2021-8-23 · Air Requirements The handpiece delivers designed speed and torque when operated with clean, filtered, moisture-free air at the recommended operating pressure of 40 psi (2.7 Atm.) for 180S, 360S, 540S series and 42 psi (2.9 Atm.) for 181S, 361S, 541S series.Air pressure should be measured at the handpiece end of the hose. Have your dealer or ...

    Get Price
  • Air Scaler AS2000 M4 B2/3 - nsk-dental.com

    2020-4-16 · Connect air scaler to the handpiece hose. In case the supply air pressure at the connection (where the scaler is connected to the handpiece hose) is set at the recommended 0.28MPa(2.9kgf/cm2), the air scaler is readily usable. X Read these cautions carefully to correctly follow the intended use.

    Get Price
  • Main Factors You Should Look For When Buying Dental ...

    Your Discount Dental Supplies Online China Supplier! Sign Up Login; My Account. Address Book; Wish List; Order History; Register; Login; Wish List (0)

    Get Price
  • Dental Handpiece Repair and Sales - Dental Equipment - DD

    Handpiece repair. With over 70 years of experience in handpiece repair and servicing, DD’s quality promise is stronger than ever. Alongside standard cartridge replacements and handpiece, motor and sonic scaler repairs – there’s also the option to upgrade to DD’s three service options, including our Premier Refresh Plan – which uses only original manufacturers parts.

    Get Price
  • Handpiece Maintenance

    Simply put, this unique device turns handpiece maintenance into an easy and consistent process. At the touch of a button, the Assistina automatically cleans spray coolant lines, sends a precise amount of lubricant through drive air channels while rotating turbines and gears, then expels excess fluid and debris-all for less than 2 cents per cycle.

    Get Price
  • Handpiece maintenance 101

    2015-4-10 · The high-speed dental handpiece is, without a doubt, one of the most commonly used and critical instruments in dental practices. Used in nearly every dental procedure, proper maintenance is essential to ensure that both the handpiece and …

    Get Price
  • 30Pcs Dental 45° Angle High Speed Handpiece 4Hole Air ...

    Find many great new & used options and get the best deals for 30Pcs Dental 45° Angle High Speed Handpiece 4Hole Air Turbine YABANG US Ship! at the best online prices at …

    Get Price